Oil and gas, petrochemicals, steel, welding, electrical utilities and civil defence all rely on flame and heat resistant PPE. The instruments here perform every heat and flame requirement of ISO 11612 (codes A to F) and EN 407, the thermal protective performance test for firefighter clothing (NFPA 1971, ASTM D4108), and the flame and radiant heat tests for full-face masks and breathing apparatus (EN 136).

Protective Clothing & PPE: fire test equipment

Full Face Mask & Breathing Apparatus Flame Tester – FTech-EN136C (EN 136, GA 124)

Full Face Mask & Breathing Apparatus Flame Tester

Integrated tester for the flame resistance of full-face masks, harnesses, straps, buckles and cylinder covers of firefighter breathing apparatus, with selectable programs and automatic result storage.

  • ModelFTech-EN136C
  • StandardsEN 136, GA 124
Request a quote
Mask Thermal Radiation Resistance Tester – FTech-EN136D (EN 136)

Mask Thermal Radiation Resistance Tester

Exposes a mask on a metal headform to radiant heat and checks leakage afterwards.

  • ModelFTech-EN136D
  • StandardsEN 136
  • Radiant heat7.0–9.0 kW/m² at 175 mm
  • Flame height40 ± 2 mm
Request a quote
Radiant Heat Transmission Tester – FTech-ISO6942 (ISO 6942, EN 366)

Radiant Heat Transmission Tester

Measures heat transmission through protective clothing materials exposed to radiant heat (ISO 11612 code C), with Windows software for control, fault detection, logging and burn prediction.

  • ModelFTech-ISO6942
  • StandardsISO 6942, EN 366
Request a quote
Thermal Protective Performance (TPP) Tester – FTech-ASTM D4108 (NFPA 1971, ASTM D4108)

Thermal Protective Performance (TPP) Tester

Combined flame and radiant exposure for firefighter clothing, gloves, shoes and helmets. Two Meker burners and nine quartz infrared tubes give an adjustable total flux of 83 ± 2 kW/m² and the TPP rating.

  • ModelFTech-ASTM D4108
  • StandardsNFPA 1971, ASTM D4108
  • Total heat flux83 ± 2 kW/m²
  • Heat flux meter0–100 kW/m², < 200 ms
Request a quote
Protective Clothing Limited Flame Spread Tester – FTech-ISO15025 (ISO 15025 (procedures A and B))

Protective Clothing Limited Flame Spread Tester

Surface and bottom-edge ignition test for flame-resistant clothing (ISO 11612 codes A1 and A2, EN 407). Stainless-steel chamber 1200 × 600 × 1200 mm and PLC touch-screen control.

  • ModelFTech-ISO15025
  • StandardsISO 15025 (procedures A and B)
Request a quote
Contact Heat Transmission Tester – FTech-ISO12127 (ISO 12127, EN 702)

Contact Heat Transmission Tester

A heated cylinder is pressed against the specimen and calorimeter under a set load to measure the threshold time (ISO 11612 code F, EN 407 contact heat).

  • ModelFTech-ISO12127
  • StandardsISO 12127, EN 702
Request a quote
Convective (Flame) Heat Transmission Tester – FTech-ISO9151 (ISO 9151, EN 367)

Convective (Flame) Heat Transmission Tester

Measures the heat transfer index of protective clothing exposed to a flame (ISO 11612 code B, EN 407 convective heat).

  • ModelFTech-ISO9151
  • StandardsISO 9151, EN 367
Request a quote
Small Splashes of Molten Metal Tester – FTech-ISO 9150 (ISO 9150, EN 348)

Small Splashes of Molten Metal Tester

Counts the molten drops from a welding rod needed to raise the temperature behind the fabric by 40 °C, for welding clothing and EN 407 gloves.

  • ModelFTech-ISO 9150
  • StandardsISO 9150, EN 348, AQ 6103
Request a quote
Molten Metal Splash Resistance Tester – FTech-ISO9185 (ISO 9185)

Molten Metal Splash Resistance Tester

Pours molten aluminium or iron onto a specimen at a set angle and judges damage on a PVC skin simulant (ISO 11612 codes D and E).

  • ModelFTech-ISO9185
  • StandardsISO 9185
Request a quote

More equipment in this section

EquipmentModelStandards
Instrumented Manikin Flame Engulfment SystemFTech-ISO13506ISO 13506-1, ISO 13506-2, ASTM F1930
Protective Gloves Convective Cold TesterFTech-EN 511AEN 511
Protective Gloves Contact Cold TesterFTech-EN 511BEN 511

Standards & classification

ISO 11612 protective clothing against heat and flame

RequirementCodeTest methodEquipment
Limited flame spreadA1 / A2ISO 15025 A / BProtective Clothing Limited Flame Spread Tester
Convective heatBISO 9151Convective (Flame) Heat Transmission Tester
Radiant heatCISO 6942Radiant Heat Transmission Tester
Molten aluminium splashDISO 9185Molten Metal Splash Resistance Tester
Molten iron splashEISO 9185Molten Metal Splash Resistance Tester
Contact heatFISO 12127Contact Heat Transmission Tester
Heat resistance at 180 °C / 260 °C—ISO 17493—
Electric arc (optional)—IEC 61482-1—
Whole garment manikin test (optional)—ISO 13506Instrumented manikin system

EN 407 protective gloves against thermal risks

PerformanceClauseTest methodEquipment
Limited flame spread6.2ISO 15025 AProtective Clothing Limited Flame Spread Tester
Contact heat6.3EN ISO 12127-1Contact Heat Transmission Tester
Convective heat6.4EN ISO 9151Convective (Flame) Heat Transmission Tester
Radiant heat6.5EN ISO 6942Radiant Heat Transmission Tester
Small splashes of molten metal6.6EN 348Small Splashes of Molten Metal Tester
Large quantities of molten metal6.7EN ISO 9185Molten Metal Splash Resistance Tester

Frequently Asked Questions

Which equipment covers all ISO 11612 code letters?

ISO 15025 (A1/A2), ISO 9151 (B), ISO 6942 (C), ISO 9185 (D and E) and ISO 12127 (F). The table on this page links each code to its tester.