Fire Testing Equipment

UL 9540A Battery Thermal Runaway Test Equipment

Cell, module, unit and installation level fire test systems for lithium-ion battery energy storage (BESS).

UL 9540A Battery Thermal Runaway Test Equipment

Fire safety data for battery energy storage projects

Utility-scale battery energy storage is growing fast in Saudi Arabia, and UL 9540A test data is requested by authorities, insurers and project owners. At cell level the method needs a pressure-rated chamber to drive cells into thermal runaway, gas chromatography to analyse the vent gas, and testers for its burning velocity, lower flammability limit and maximum explosion pressure. We also supply large calorimetry systems from 1 to 20 MW for module, unit and installation level tests.

Battery & Energy Storage (UL 9540A): fire test equipment

Lithium Battery Thermal Runaway & Explosion Chamber (UL 9540A)

Lithium Battery Thermal Runaway & Explosion Chamber

Pressure-rated chamber for thermal runaway, fire and explosion tests of lithium cells, with heating, pressure and temperature measurement, air purge, nitrogen charging, vacuum and gas sampling systems.

  • StandardsUL 9540A
Request a quote
Gas Chromatography & Gas Collection System – Agilent 8890 (UL 9540A)

Gas Chromatography & Gas Collection System

Analyses the composition of gases vented by cells in thermal runaway, a key input to UL 9540A reports, with Agilent MassHunter software.

  • ModelAgilent 8890
  • StandardsUL 9540A
Request a quote
Combustible Gas Burning Velocity Tester (UL 9540A, ISO 817 Annex C)

Combustible Gas Burning Velocity Tester

A high-speed camera records the flame travelling through a vertical quartz tube filled with battery vent gas to determine its burning velocity.

  • StandardsUL 9540A, ISO 817 Annex C
  • TubeQuartz, Ø 40 mm, 1.2 m
  • Gas supply33 L/min with mixing vessel
Request a quote
Combustible Gas Explosion Limit Tester (UL 9540A, EN 15967)

Combustible Gas Explosion Limit Tester

Measures the lower flammability limit (LFL) and maximum explosion pressure (Pmax) of battery vent gases in a 20 L stainless-steel sphere.

  • StandardsUL 9540A, EN 15967, ASTM E918 …
  • Vessel20 L, rated 5.0 MPa
  • Temperature-10 to 250 °C, ±1 °C
Full specifications
StandardsUL 9540A, EN 15967, ASTM E918, ASTM E2079
Vessel20 L, rated 5.0 MPa
Temperature-10 to 250 °C, ±1 °C
Pressure0–110 kPa, ±0.1 % FS
Request a quote

More equipment in this section

EquipmentModelStandards
Battery Enclosure Sand-Blasting / Flame TesterFTech-UL 2596UL 2596
1–20 MW Battery Thermal Release Test System—UL 9540A (unit and installation level)

Frequently Asked Questions

What data does UL 9540A cell-level testing produce?

Thermal runaway onset temperature, vent gas volume and composition, lower flammability limit, burning velocity and maximum explosion pressure. These results decide whether module and unit level tests are needed.

Equip your Battery & Energy Storage (UL 9540A) fire testing laboratory

Share the products and standards you test to, and EnmaTech will recommend the right equipment for your laboratory in Saudi Arabia and prepare a quotation.