Fire Testing Equipment

Fire Testing Equipment for Cables & Wires

Flame spread, heat release, smoke, halogen acid gas and circuit integrity testers for power, control, data and optical cables.

Fire Testing Equipment for Cables & Wires

From LSZH claims to CPR classes and fire-resistant circuits

Cable makers and testing laboratories need to prove flame retardance, low smoke, zero halogen and circuit integrity during fire. This range covers single and bunched cable flame tests (IEC 60332-1 and -3), heat release and smoke for CPR classification (EN 50399), fire resistance with mechanical shock and water spray (IEC 60331, BS 6387), the 3 m cube smoke test (IEC 61034), halogen acid gas (IEC 60754) and the UL 910 / NFPA 262 Steiner tunnel for plenum cables.

Cables & Wires: fire test equipment

Halogen Acid Gas Content Tester – FTech-IEC 60754 (IEC 60754-1, IEC 60754-2)

Halogen Acid Gas Content Tester

Burns cable materials in a tube furnace and determines the amount of halogen acid gas, pH and conductivity of the gases, the basis for low-smoke zero-halogen (LSZH) claims.

  • ModelFTech-IEC 60754
  • StandardsIEC 60754-1, IEC 60754-2
Request a quote
Single Cable Vertical Flame Tester – FTech-IEC 60332-1 (IEC 60332-1-1, -2)

Single Cable Vertical Flame Tester

Vertical flame propagation test for a single insulated wire, cable or optical cable, including the behaviour of flaming droplets.

  • ModelFTech-IEC 60332-1
  • StandardsIEC 60332-1-1, -2, -3 …
Full specifications
ModelFTech-IEC 60332-1
StandardsIEC 60332-1-1, -2, -3, EN 50086-1
Request a quote
Bunched Cables Vertical Flame & Heat Release Tester – FTech-IEC 60332-3 / FTech-EN 50399 (IEC 60332-3-10 to -25, UL 1685)

Bunched Cables Vertical Flame & Heat Release Tester

Tests vertically mounted bunched cables (categories A to D). With the optional EN 50399 measuring system it adds heat release and smoke measurement for CPR cable classification (Cca to Eca).

  • ModelFTech-IEC 60332-3 / FTech-EN 50399
  • StandardsIEC 60332-3-10 to -25, UL 1685, IEEE 383 …
  • Gas analysisParamagnetic O2, infrared CO2
  • SmokeHe-Ne laser photometer
Full specifications
ModelFTech-IEC 60332-3 / FTech-EN 50399
StandardsIEC 60332-3-10 to -25, UL 1685, IEEE 383, IEEE 1202, EN 50399
Gas analysisParamagnetic O2, infrared CO2
SmokeHe-Ne laser photometer
ResultsHRR, SPR, O2, CO2
Request a quote
Cable Fire Resistance, Impact & Water Spray Tester – FTech-IEC 60331 (IEC 60331-1, IEC 60331-2)

Cable Fire Resistance, Impact & Water Spray Tester

Checks circuit integrity of fire-resistant cables under fire, fire with mechanical shock and fire with water spray. All three tests run from one control cabinet and touch screen.

  • ModelFTech-IEC 60331
  • StandardsIEC 60331-1, IEC 60331-2, IEC 60331-11 …
Full specifications
ModelFTech-IEC 60331
StandardsIEC 60331-1, IEC 60331-2, IEC 60331-11, IEC 60331-21, IEC 60331-31, BS 6387
Request a quote
3 Metre Cube Cable Smoke Density Apparatus – FTech-IEC 61034 (IEC 61034-1, IEC 61034-2)

3 Metre Cube Cable Smoke Density Apparatus

Measures light transmittance through the smoke of cables burned horizontally in a 27 m³ chamber, the standard smoke test for LSZH cables.

  • ModelFTech-IEC 61034
  • StandardsIEC 61034-1, IEC 61034-2
Request a quote
Steiner Tunnel (Plenum Cable & ASTM E84) – FTech-UL910 / FTech-ASTM E84 (UL 910, NFPA 262)

Steiner Tunnel (Plenum Cable & ASTM E84)

Horizontal 7.6 m tunnel for the most demanding UL cable rating (CMP plenum) and for surface burning characteristics of building materials. Specimens burn for 20 minutes under an 87.9 kW burner while flame spread and smoke are recorded.

  • ModelFTech-UL910 / FTech-ASTM E84
  • StandardsUL 910, NFPA 262, ASTM E84 …
  • Chamber305 × 451 mm, 7.6 m long
  • Burner87.9 kW (300,000 BTU/h)
Full specifications
ModelFTech-UL910 / FTech-ASTM E84
StandardsUL 910, NFPA 262, ASTM E84, UL 723
Chamber305 × 451 mm, 7.6 m long
Burner87.9 kW (300,000 BTU/h)
Fan3 kW, variable frequency
Request a quote

More equipment in this section

EquipmentModelStandards
Microscale Combustion CalorimeterFTech-ASTM D7309ASTM D7309
Carbon Black Content TesterFTech-ASTM D5630ASTM D5630
Vertical Tray Cable Flame Tester (VW-1)FTech-UL1581UL 1581, ASTM D5025, ASTM D5207
Cable Fire Protection Component TesterFTech-UL1685UL 1685, IEEE 1202
HCF Cable Fire Resistance Tester (Offshore)FTech-NEK 606NEK 606, IEC 60092, IEC 60331
Busway / Bus Duct Fire Resistance FurnaceFTech-GAT537GA/T 537, IEC 60331
NF C32-070 Cable Combustion TesterFTech-NFC32-070NF C32-070, UL 2556
Riser Cable Vertical Flame Tester (Shaft)FTech-UL1666UL 1666

Frequently Asked Questions

Which tests prove a cable is LSZH?

Low smoke is shown with the IEC 61034 3 m cube test and zero halogen with IEC 60754-1 and -2. Flame retardance is usually shown with IEC 60332-1 and IEC 60332-3.

Can the bunched cable tester be upgraded for EN 50399?

Yes. The optional heat release system adds the exhaust duct, gas analysis and smoke measurement required by EN 50399 for CPR classes.

Equip your Cables & Wires fire testing laboratory

Share the products and standards you test to, and EnmaTech will recommend the right equipment for your laboratory in Saudi Arabia and prepare a quotation.