Laboratory Equipment

Sample Digestion & Kjeldahl Analysis

Equipment that digests samples in acid and measures nitrogen and protein in food, feed, grain, soil, fertiliser and plant tissue, for laboratories across Saudi Arabia.

Sample Digestion & Kjeldahl Analysis

The reference method for protein and nitrogen

Kjeldahl analysis remains one of the most trusted reference methods in agricultural and food laboratories, and the equipment on this page covers each step. Samples are digested in concentrated acid on a temperature-controlled block or heating plate, the acid fumes are collected and neutralised, and an automatic Kjeldahl analyser distils and titrates the digest to report nitrogen and crude protein. Programmable graphite and aluminium heating plates also prepare samples for metal analysis. Feed mills, food control laboratories, grain quality laboratories, soil and fertiliser laboratories and universities in Saudi Arabia rely on this equipment every day. EnmaTech supplies, installs and supports it, and helps plan complete digestion areas.

Digestion & Kjeldahl Equipment

Automatic Kjeldahl Nitrogen Analyzer (7-inch screen)

Automatic Kjeldahl Nitrogen Analyzer (7-inch screen)

Nitrogen and protein analyser that finds the end point through automatic distillation and colorimetric titration, for soil, food, feed, agricultural products and other samples containing nitrogen.

  • Analysis range0.1-240 mg N
  • Precision (RSD)≤0.5%
  • Recovery≥99.5% (±0.5%)
  • Titration accuracy0.75 µL/step
Features & full specifications

Key features

  • 7-inch color touch screen with on-screen methods and maintenance guidance
  • Automatic shutdown after 60 minutes idle
  • RGB color sensors with three titration curves
  • Titration accuracy verification
  • Surface-mounted titration cup
  • Linear-motor syringe titration pump
  • Built-in protein coefficient table
  • Stores 100,000 results; built-in 5.7 cm thermal printer
  • 99 user-defined programs
  • 304 stainless steel steam generator

Technical specifications

Analysis range0.1-240 mg N
Precision (RSD)≤0.5%
Recovery≥99.5% (±0.5%)
Titration accuracy0.75 µL/step
Analysis time4-6 min per sample (cooling water 18 °C)
Titrant concentration0.01-5 mol/L
Alkali dosing0-999 s
PowerAC220 V/50 Hz, 2000 W heating
Dimensions500 x 460 x 710 mm
Net weight36 kg
Request a quote
Automatic Kjeldahl Nitrogen Analyzer (10-inch screen)

Automatic Kjeldahl Nitrogen Analyzer (10-inch screen)

Fully automatic nitrogen and protein analyser with a 10-inch touch screen, a distil-while-titrating mode, automatic waste discharge and the option to run on a recirculating chiller. Available in two versions.

  • Analysis range0.1-210 mg N
  • Precision (RSD)≤0.5%
  • Recovery≥99.5% (±0.5%)
  • Titration accuracy0.75 µL/step
Features & full specifications

Key features

  • 10-inch color touch screen
  • Automatic shutdown after 60 minutes idle
  • RGB titration curves and titration accuracy verification
  • Automatic upload of sample weighing data
  • USB data export; Windows-based system with screen sync
  • Works with a cold-water circulation chiller (no tap water)
  • Distillation while titrating to save time
  • Automatic digestion waste discharge
  • Adjustable 50-100% steam flow
  • Automatic alkali pipeline cleaning; cooling water flow monitoring

Available configurations

  • Version A (one of two cabinet styles shown)
  • Version B (second cabinet style shown)

Technical specifications

Analysis range0.1-210 mg N
Precision (RSD)≤0.5%
Recovery≥99.5% (±0.5%)
Titration accuracy0.75 µL/step
Analysis time4-6 min per sample
Titrant concentration0.01-5 mol/L
Steam flow50-100%
PowerAC220 V/50 Hz, 2000 W heating
Dimensions500 x 460 x 710 mm
Net weight36 kg
Request a quote
Automatic Kjeldahl Nitrogen Analyzer with 40-Position Autosampler

Automatic Kjeldahl Nitrogen Analyzer with 40-Position Autosampler

Fully automatic nitrogen and protein analyser delivered with a 40-position autosampler and a desktop computer, featuring a distil-while-titrating mode and chiller-based cooling.

  • Analysis range0.1-240 mg N
  • Precision (RSD)≤0.5%
  • Recovery≥99.5% (±0.5%)
  • Titration accuracy0.75 µL/step
Features & full specifications

Key features

  • 40-position autosampler
  • 10-inch color touch screen
  • Automatic weighing data upload and USB export
  • RGB titration curves; titration accuracy verification
  • Cold-water circulation chiller support
  • Distillation while titrating
  • Automatic waste discharge
  • 50-100% adjustable steam flow
  • Cooling water flow monitoring
  • Supplied with a desktop computer

Technical specifications

Analysis range0.1-240 mg N
Precision (RSD)≤0.5%
Recovery≥99.5% (±0.5%)
Titration accuracy0.75 µL/step
Analysis time4-6 min per sample
Titrant concentration0.01-5 mol/L
Safe alkali dosing0-99 s
Autosampler40 positions
PowerAC220 V/50 Hz, 2000 W
Printer5.7 cm thermal, automatic paper cutting
Request a quote
Constant Temperature Digestion Block (8-hole)

Constant Temperature Digestion Block (8-hole)

Digestion block built on the classical wet digestion principle, used to break down plant, seed, feed, soil, ore and other samples ahead of chemical analysis.

  • Sample holes8
  • ApertureØ43.5 mm
  • Heating module6061 aluminum
  • Design temperature450 °C
Features & full specifications

Key features

  • Redesigned heating system with improved hole-to-hole temperature uniformity
  • Aluminum alloy heating module with aviation-grade coating; 450 °C design temperature
  • LCD controller with timed shutdown, alarm and PID control
  • Brushed stainless steel body and tube rack

Technical specifications

Sample holes8
ApertureØ43.5 mm
Heating module6061 aluminum
Design temperature450 °C
Control accuracy±1 °C
Heating rate≈8-15 °C/min
Timed shutdown1-999 min
PowerAC220 V/50 Hz, 2.2 kW
Request a quote
Programmable Electric Heating Plate (Aluminum)

Programmable Electric Heating Plate (Aluminum)

Laboratory heating plate for heating, drying, digesting and acid removal in grain, agricultural, soil, environmental and food laboratories. Available in three plate sizes.

  • Plate size300 x 200 to 600 x 400 mm
  • Plate materialCoated aluminum alloy
  • Design temperatureRT-350 °C
  • Accuracy±1 °C
Features & full specifications

Key features

  • 6061 aluminum alloy coated heating body, up to 350 °C
  • Ventilation and cooling for the control area
  • Overtemperature protection sensor
  • 304 stainless steel table sprayed with PTFE
  • 5-inch color touch screen, Chinese/English
  • 0-40 segment programs; single-point or curve heating
  • PID self-tuning control with solid-state relay
  • Power failure recovery and restart

Available configurations

  • 300 x 200 mm plate, 1500 W
  • 400 x 300 mm plate, 3000 W
  • 600 x 400 mm plate, 4000 W

Technical specifications

Plate size300 x 200 to 600 x 400 mm
Plate materialCoated aluminum alloy
Design temperatureRT-350 °C
Accuracy±1 °C
Controller5.5 inch color touch screen, 1-40 curve programs
Recipes9 groups
Timed shutdown1-999 min
VoltageAC220 V/50 Hz
Heating power1500-4000 W
Request a quote
Programmable Graphite Heating Plate

Programmable Graphite Heating Plate

Laboratory heating plate with a high-density graphite surface that reaches 550 °C, for heating, drying, digesting and acid removal.

  • Plate size400 x 300 mm
  • Plate materialGraphite
  • Design temperatureRT-550 °C
  • Accuracy±1 °C
Features & full specifications

Key features

  • High-density graphite heating body, up to 550 °C, uniform temperature
  • Overtemperature protection sensor
  • 304 stainless steel PTFE-sprayed table
  • 5-inch color touch screen, Chinese/English
  • 0-40 segment programs; single-point or curve heating
  • PID self-tuning control; solid-state relay
  • Power failure recovery and restart

Technical specifications

Plate size400 x 300 mm
Plate materialGraphite
Design temperatureRT-550 °C
Accuracy±1 °C
Controller5.5 inch color touch screen, 1-40 curve programs
Recipes9 groups
Timed shutdown1-999 min
VoltageAC220 V/50 Hz
Heating power3000 W
Request a quote
Acid Fume Collector for Digestion Block

Acid Fume Collector for Digestion Block

Acid gas hood for digestion blocks that collects the acid mist released during digestion and sends it to a neutralisation unit for treatment before it is discharged.

  • Collection ports8, 10, 15 or 20
  • Exhaust ports1-2
  • Shell316 stainless steel
Features & full specifications

Key features

  • Sealing cover of molded fluoroelastomer (FPM), resistant to heat, acid and alkali
  • Collecting pipes reach deep into each tube
  • Welded 316 stainless steel shell
  • Several sizes available

Available configurations

  • 8 ports, 1 exhaust
  • 10 ports, 1 exhaust
  • 15 ports, 2 exhausts
  • 20 ports, 2 exhausts

Technical specifications

Collection ports8, 10, 15 or 20
Exhaust ports1-2
Shell316 stainless steel
Request a quote
Acid Mist Neutralization Device

Acid Mist Neutralization Device

Two-stage unit that collects, neutralises and filters acid mist from sample digestion: an alkali stage neutralises the mist and a distilled-water stage scrubs the remaining gas so the exhaust meets discharge standards.

Features & full specifications

Key features

  • Built-in negative pressure air pump with large flow and long life
  • Two-stage absorption (alkali liquor + distilled water)
  • Large gas-liquid contact surface, high neutralization efficiency
  • Simple, safe and reliable
  • Easy solution replacement
Request a quote

Protein in food and feed

Multiplying Kjeldahl nitrogen by a protein factor gives crude protein, a core figure for feed formulation, food labelling and the pricing of grain and oilseed meal.

Nitrogen in soil and plants

Total nitrogen in soil and plant tissue shapes fertiliser recommendations and supports research into nitrogen use efficiency, a key factor in sustainable farming.

Preparing samples for metal analysis

Programmable heating plates digest food, plant and soil samples in acid to release metals for atomic absorption analysis, following controlled temperature profiles for repeatable results.

Safer acid fume handling

Fume collectors and neutralisation units capture and neutralise acid vapour from digestion, protecting staff, instruments and the building exhaust system.

Frequently Asked Questions

How many samples can we run at once?

The digestion block shown here takes eight tubes per run, and the analyser with a 40-position autosampler distils and titrates a full batch without supervision, which suits laboratories with heavy daily workloads.

Do we still need Kjeldahl if we already have an NIR analyser?

Yes. Kjeldahl is the reference method used to calibrate and check NIR protein predictions. Laboratories that screen routinely by NIR still run Kjeldahl on reference and control samples.

Should we choose a graphite or an aluminium heating plate?

Graphite plates resist acid corrosion and heat evenly, so they suit open-vessel acid digestion. Aluminium plates are a cost-effective choice for general heating where acid exposure is limited.

Plan your digestion area